Use of Engine Driven Generators - Single Phase or Three Phase

This list shows minimum generator sizes based on typical 80°C rise continuous duty generators, with 35% maximum voltage dip during starting, for Franklin's three -wire motors, single or three phase.

This is a general chart. The generator manufacturer should be consulted whenever possible, especially on larger sizes.

There are two types of generators available: externally and internally regulated. Most are externally regulated. They use an external voltage regulator that senses the output voltage. As the voltage dips at motor start-up, the regulator increases the output voltage of the generator.

Internally regulated (self-excited) generators have an extra winding in the generator stator. The extra winding senses the output current to automatically adjust the output voltage.

Generators must be sized to deliver at least 65% of the rated voltage during starting to ensure adequate starting torque. Besides sizing, generator frequency is important as the motor speed varies with the frequency (Hz). Due to pump affinity laws, a pump running at 1 or 2 Hz below nameplate frequency design will not meet its performance curve. Conversely, a pump running at 1 to 2 Hz above may trip overloads.

Generator Operation
Always start the generator before the motor is started and always stop the motor before the generator is shut down. The motor thrust bearing may be damaged if the generator is allowed to coast down with the motor running. This same condition occurs when the generator is allowed to run out of fuel.

Follow generator manufacturer's recommendations for de-rating at higher elevations or using natural gas.

MOTOR RATING MINIMUM RATING OF GENERATOR
HP KW EXTERNALLY REGULATED INTERNALLY REGULATED
KW KVA KW KVA
1/3 0.25 1.5 1.9 1.2 1.5
1/2 0.37 2 2.5 1.5 1.9
3/4 0.55 3 3.8 2 2.5
1 0.75 4 5.0 2.5 3.13
1.5 1.1 5 6.25 3 3.8
2 1.5 7.5 9.4 4 5
3 2.2 10 12.5 5 6.25
5 3.7 15 18.75 7.5 9.4
7.5 5.5 20 25.0 10 12.5
10 7.5 30 37.5 15 18.75
15 11 40 50 20 25
20 15 60 75 25 31
25 18.5 75 94 30 37.5
30 22 100 125 40 50
40 30 100 125 50 62.5
50 37 150 188 60 75
60 45 175 220 75 94
75 55 250 313 100 125
100 75 300 375 150 188
125 90 375 469 175 219
150 110 450 563 200 250
175 130 525 656 250 313
200 150 600 750 275 344
NOTE: For best starting of 2-wire motors, the minimum generator rating of 50% higher than shown.
WARNING: To prevent accidental electrocution, automatic or manual transfer switches must be used any time a generator is used as standby or back up on power lines. Contact power company for use and approval.



Technical Resources feed

 

25% off

DWM 150 VOX A - 230 V

MRP:£846.00

Our price Only:
£634.50
+ VAT

20% off

AGC 2.00 M 240V

MRP:£554.00

Our price Only:
£443.20
+ VAT

36% off

Right 100 M A. 230 V

MRP:£508.00

Our price Only:
£325.00
+ VAT

50% off

DOC 3SG/A 230V

MRP:£260.00

Our price Only:
£130.00
+ VAT